Home / Product / Earth Resistance Tester / Double Clamp/Four Clamp Earth Resistance Tester / ETCR EM3200C Double Clamp Earth Resistance Tester
    ETCR EM3200C Double Clamp Earth Resistance Tester
  • Product Series : Double Clamp/Four Clamp Earth Resistance Tester

    • Main Features

      Grounding resistance measurement, DC resistance measurement, soil resistivity measurement, ground voltage measurement, grounding current measurement

      Grounding resistance range: 0.000Ω~300kΩ

      DC resistance range: 0.000Ω~300kΩ

      Soil resistivity range: 0.00Ωm~9999kΩm

      Grounding voltage range: AC 0.0V~100.0V

      Grounding current range: 0.0mA~600.0A

      Jaw size: Φ70mm

      Storage function: 2000 data sets

      Alarm function: Configurable alarm threshold

      USB communication interface

      Bluetooth communication

      Rechargeable lithium battery

    Product Introduction

    The ETCR EM3200C dual-clamp grounding resistance tester, also known as a multi-functional grounding resistance tester or precision grounding resistance tester, is used for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding wire leakage current, AC current, and DC resistance. The instrument employs digital processing technology and supports precise 4-wire, 3-wire, simplified 2-wire, selection, and dual-clamp methods for measuring grounding resistance. It can flexibly and accurately measure any grounding resistance value under various complex grounding conditions, including single-point and mesh grounding. When measuring parallel grounding, no parallel grounding electrodes need to be disconnected, maximizing measurement convenience. It incorporates FFT (Fast Fourier Transform) and AFC (Automatic Frequency Control) technologies, possessing unique anti-interference capabilities and environmental adaptability. Its strong repeatability ensures high accuracy, stability, and reliability for long-term measurements. It is widely used in industries such as power, telecommunications, meteorology, construction, lightning protection, and industrial electrical equipment.


    The ETCR EM3200C dual-clamp grounding resistance tester consists of a main unit, current clamps (dual clamps), data software, test leads, auxiliary grounding rods, and communication cables. The instrument features a large-diameter current clamp design, capable of meeting testing needs in various situations. It can measure the grounding resistance of large-sized grounding leads. The main unit has a large LCD display with backlight and bar graph indicators for easy reading. The instrument supports Bluetooth communication with Android systems; after installing the APP, testing and reading test records can be performed on mobile devices, providing a brand-new experience. The instrument has storage and clock functions, automatically storing 2000 sets of test results with date and time. Data software via USB interface allows for historical data reading, viewing, saving, reporting, and printing.


    Product Features:

    1. Measures grounding resistance using two-, three-, and four-wire methods, selection methods, and dual-clamp methods.


    2. Uniquely designed socket indicator lights accurately indicate socket positions, avoiding operational errors.


    3. A 12-position function selection knob clearly displays various testing methods, making operation simple and fast.


    4. Incorporating FFT (Fast Fourier Transform) and AFC (Automatic Frequency Control) technologies, it possesses unique anti-interference capabilities and environmental adaptability, with strong consistency in repeated tests.


    5. Large LCD display on the main unit with white backlight and bar graph indicators for clear and easy reading.


    6. Alarm function with adjustable alarm thresholds.


    7. Storage function for 2000 data entries.


    8. USB communication interface for data upload.


    9. Bluetooth communication function.


    10. Rechargeable lithium battery.


    Technical Parameters

    Measurement FunctionsMeasurement RangeAccuracyResolution
    Two-, three-, and four-wire methods for measuring grounding resistance (R~) and DC resistance (R—).0.000Ω~9.999Ω±2%rdg±0.05Ω0.001Ω
    10.00Ω~29.99Ω±2%rdg±5dgt0.01Ω
    30.0Ω~299.9Ω±2%rdg±3dgt0.1Ω
    300Ω~2999Ω±2%rdg±3dgt
    3.00kΩ~300.00kΩ±4%rdg±3dgt10Ω
    Selective method for measuring grounding resistance (R~)0.000Ω~9.999Ω±2%rdg±0.05Ω0.001Ω
    10.00Ω~29.99Ω±2%rdg±5dgt0.01Ω
    30.0Ω~299.9Ω±2%rdg±3dgt0.1Ω
    300Ω~3000Ω±2%rdg±3dgt
    Dual-clamp method for measuring grounding resistance (R~)0.01Ω~0.99Ω±10%rdg±5dgt0.01Ω
    1.0Ω~29.9Ω0.1Ω
    30Ω~100Ω
    Soil resistivity (ρ)0.00Ωm~99.99ΩmIt depends on the measurement accuracy of R.(ρ=2πaR a:1 m~100m; π=3.14)0.01Ωm
    100.0Ωm~999.9Ωm0.1Ωm
    1000Ωm~9999Ωm1Ωm
    10.00kΩm~99.99kΩm10Ωm
    100.0kΩm~999.9kΩm100Ωm
    1000kΩm~9999kΩm1kΩm
    Grounding voltage (V~) 50Hz/60HzAC 0.0V~100.0V±2%rdg±3dgt0.1V
    Grounding current (A~) 50Hz/60HzAC 0.00mA~600.0A±2%rdg±3dgt0.01mA

    2、Standard Specifications

    Specification NameSpecifications
    Power SupplyDC 7.4V 2600mAh rechargeable lithium battery, approximately 8.4V when fully charged
    Display Mode4-digit large LCD display with backlight
    Measurement IndicatorLED flashing indicator during measurement, LCD countdown display
    LCD Size128mm × 75mm; Display Area: 124mm × 67mm
    BacklightControllable backlight, suitable for use in dimly lit environments
    Measurement methodsDC resistanceDC Resistance Two-Electrode Method
    DC Resistance Four-Electrode Method
    Grounding resistanceGrounding Resistance Two-Electrode Method
    Grounding Resistance Three-Electrode Method
    Grounding Resistance Four-Electrode Method
    Grounding Resistance Single-Clamp Three-Electrode Method (Selection Method)
    Grounding Resistance Single-Clamp Four-Electrode Method (Selection Method)
    Grounding Resistance Double-Clamp Method
    Soil Resistivity (Wenner Method)
    Grounding currentCurrent Clamp Measurement
    Grounding voltageAverage Rectification
    Test Frequency128Hz/111Hz/105Hz/94Hz(AFC Auto Frequency Selection)
    Short Circuit Test CurrentAC 250mA max
    Open Circuit Test VoltageAC 40V max
    Electrode Spacing Range1m~100m
    Test Leads4: One each of red (20m), black (20m), yellow (10m), and green (10m)
    Simple Test Leads2: One each of red (1.6m) and black (1.6m)
    Auxiliary Grounding Rods4: φ9mm×230mm (approx. 696g)
    Current Clamps2: One each of blue-black plug and red-black plug
    Current Clamp Jaw Diameterφ70mm
    Current Clamp DimensionsH x W x D: 223mm x 120mm x 39mm
    Measurement TimeAC current: approx. 2 times/second; Voltage to ground: approx. 2 times/second; Grounding resistance: approx. 7 seconds/time
    Line voltageMeasured below AC 600V
    Communication methodBluetooth module, USB interface; stored data can be uploaded to a computer via software.
    Data hold"HOLD" symbol indicates data hold.
    Data storage2000 sets; "FULL" symbol indicates storage is full.
    Data RetrievalThe "READ" symbol indicates data retrieval.
    Overflow DisplayThe "OL" symbol indicates over-range overflow.
    Interference TestAutomatically identifies interference signals; the "NOISE" symbol indicates an interference voltage higher than 5V.
    Auxiliary Grounding TestFeatures auxiliary grounding resistance testing, 0.00kΩ~30.00kΩ (100R+rC<50kΩ, 100R+rP<50kΩ).
    Alarm FunctionA "beep-beep-beep" alarm sounds when the measured value exceeds the alarm setting.
    Alarm Threshold Setting RangeResistance: 0Ω~9999Ω, Voltage: 0.0V~100.0V, Current: 0.000A~9.9999A
    Automatic ShutdownAutomatically shuts down 15 minutes after power-on.
    Operating CurrentBacklight: 25mA Max (backlight power consumption only); Standby: 25mA Max (Backlight off after power-on); Measurement: 150mA Max (Backlight off)
    Instrument DimensionsHeight x Width x Depth: 280mm x 260mm x 160mm
    WeightInstrument: Approx. 1799g (including battery); Total Weight: Approx. 6.13kg (including accessories)
    Battery VoltageWhen the battery voltage drops to approximately DC 7.2V ± 0.1V, a low battery indicator will appear, reminding the instrument to recharge.
    Protection RatingIP65 (with cover closed)
    Overload ProtectionMeasuring grounding resistance: AC 280V/3 seconds between C(H)-E and P(S)-ES ports
    Insulation ResistanceAbove 20MΩ (500V between circuit and casing)
    Withstand VoltageAC 3700V/rms (between circuit and casing)
    Electromagnetic CharacteristicsIEC61326(EMC)
    Safety ComplianceIEC61010-1 (CAT III) 300V, CAT IV 150V, Pollution Degree 2); IEC61010-031; IEC61557-1 (Grounding Resistance); IEC61557-5 (Soil Resistivity); JJG 366-2004 (Grounding Resistance Meter); JJG 1054-2009 (Clamp-on Grounding Resistance Meter).
    Operating Temperature and Humidity-10℃~40℃;80%RH以下
    Storage Temperature and Humidity-20℃~60℃;70%RH以下


    Model Comparison


    roduct PicturesProduct Model NameResistance RangeSoil Resistivity RangeVoltage RangeCurrent RangeAlarm FunctionOther
    EM3000 (1).jpgETCR EM30000.00Ω~2000Ω--0~600V--Yes

    Data Storage

    IP65

    EM3000B (1).jpgETCR EM3000B0.00Ω~30.00kΩ0.00Ωm~9000kΩ
    0~600V--Yes

    Data Storage

    IP65

    EM3000C (1).jpgETCR EM3000C0.00Ω~2000Ω--
    0~600V--Yes

    USB Communications

    Data Storage

    IP65

    EM3040 (1).jpgETCR EM30400.00Ω~2000Ω--0~300V--
    Yes--
    EM3100C (2)~1.jpgETCR EM3100C0.00Ω~30.00kΩ0.00Ωm~9000kΩ0~600V--YesUSB communication

    Bluetooth communication

    Data Storage

    IP65

    EM3200C (1)~1.jpgETCR EM3200C0.00Ω~300kΩ0.00Ωm~9000kΩ0~100V0.00mA~600.0AYes

    USB communication

    Bluetooth communication

    Data Storage

    IP65


    Product Video

    Related Products
    ETCR EM3200C Double Clamp Earth Resistance Tester
    • Contact Us

    +86 13802922567 (Johnson Zhang)

    [email protected]

    10th Floor, Block 5, Liandong Intelligent Manufacture Park, No. 105, Shilong North Road, Nanhai District, Foshan City, Guangdong, China

    All Rights Reserved © Guangdong ETCR Electronic Technology CO.,Ltd 2025
    Site Map
    Independent Station

    Home
    Tel
    Product
    Contact