Product Series : Double Clamp Digital Phase Voltmeter
Used to measure single-phase AC phase, current, voltage, leakage current, phase sequence and other power parameters
Clamp jaw size: Φ8mm
Voltage range: AC 0V~600V
Current range: AC 0A~20A
Phase range: 0°~360°
Product Introduction
ETCR EM4000 Double Clamp Digital Phase Voltmeter, also known as single-phase phase voltammeter, digital phase voltammeter, voltammeter, phase measuring instrument, is used for phase, AC current, AC voltage, AC leakage current, and phase sequence measurement.The AC voltage and AC current can be directly measured when the circuit under test is not open, and the phase between the two voltages, the two currents, and the voltage and current can be measured. In addition, the power factor and power of the circuit can be indirectly measured, and the three-phase phase sequence, transformer wiring group, inductive, capacitive circuit, test the secondary circuit and the female difference protection system, read out the phase relationship between the CT of the various groups of mobile protection, check whether the wiring of the meter is correct, and overhaul the line equipment.It is suitable for electric power, petrochemical, metallurgy, railways, meteorology, industrial and mining enterprises, scientific research institutions, metrology departments, etc.
ETCR EM4000 Double Clamp Digital Phase Voltmeter adopts a large LCD display screen with white screen backlight, and the display is clear at a glance. The instrument adopts an insulated non-slip sheath, has a data retention function, automatic shutdown function, simple operation, reliable and durable.
1. Input by voltage transformer and current clamp, there is no high voltage in the machine, and the two inputs are completely isolated, which is safe and reliable.
2. The pointed and small jaws are suitable for places with dense wiring.
3. The test line adopts a special power cable, and the elastic rod plug and alligator clip are insulated and protected.
4. The use of large LCD display, white screen backlight, the display is clear at a glance.
5. High precision, high stability, low power consumption, and easy operation.


Technical Parameters
1.Range & Basic Error
| Category | Range | Resolution | Basic Error |
| Voltage | 20V | 0.01V | ±(0.5% range) |
| 200V | 0.1V | ||
| 600V | 1V | ||
| Current | 200mA | 0.1mA | ±(0.5% range) |
| 2A | 1mA | ||
| 20A | 10mA | ||
| Phase | 0~360° | 1° | ±1° |
2.General Specifications
| Power Supply | DC9V Alkaline dry battery (1.5V LR6X6) |
| Display Mode | LCD display, white screen backlight function, suitable for dim places |
| LCD Size | 70mmX62mm; display area: 64mmX54mm |
| Clamp Jaw Size | Φ8mm |
| Sampling Rate | 3 times/second |
| Range | AC voltage: 0~20V/200V/600V |
| AC current: 0~200mA/2A/20A | |
| Phase: 0~360° | |
| The Amplitude Range Of The Measured Signal When Measuring The Phase | When measuring the phase of U1-U2: 30V~600V |
| When measuring the phase of I1-I2: 10mA~20.00A | |
| When measuring the phase of U1-I2 or I1-U2: 10V~500V, 10mA~20.00A | |
| Data Hold | Press the HOLD key to hold the data during the test, and the ”DH" symbol is displayed |
| Automatic Shutdown | After about 15 minutes of power-on, the meter automatically shuts down to reduce battery consumption |
| Voltage Detection | When the battery voltage is lower than 7.8V~8V, the low battery voltage symbol is displayed to remind the battery to be replaced. |
| Working Current | Turn on the backlight up to about 35mA |
| Turn off the backlight, the meter consumes about 5mA of power | |
| Instrument Size | 196mmX92mmX54mm |
| Weight | Host: about 565g (include battery); total weight: about 2.24kg (include accessories) |
| Insulation | ≥10MW between the instrument line and the housing, between the two voltage input terminals |
| Structure | Double insulation |
| Input Impedance | The input impedance of each gear of the test voltage is: 1MΩ |
| When measuring the phase of U1U2, the voltage input impedance is: 40kΩ | |
| Withstand Voltage | The sine wave AC voltage of 1000V/50Hz can be tolerated between the instrument line and the housing for 1 minute; the sine wave AC voltage of 500V/50Hz can be tolerated between the two voltage input terminals for 1 minute. |
| Working Temperature & Humidity | -10℃~40℃; below80%RH |
| Store Temperature & Humidity | -10℃~60℃; below70%RH |
Model Comparison
| Product Picture | Product Model Name | Clamp Jaw Size | Phase | Voltage Range | Current Range | Power Range | Harmonic |
![]() | ETCR EM4000 Double Clamp Digital Phase Voltmeter | Φ8mm | 0~360° | 0.00V~600V | 0.0mA~20.0A | -- | -- |
![]() | ETCR EM4000A Double Clamp Digital Phase Voltmeter | Φ8mm | 0~360° | 0.00V~600V | 0mA~600A | 0.0W~12kW | -- |
![]() | ETCR EM4020 Large Caliber Double Clamp Digital Phase Voltmeter | Φ40mm | 0~360° | 0.00V~600V | 0.0mA~20.0A | 0.0W~360kW | -- |
![]() | ETCR EM4300 Three Phase Digital Phase Voltmeter | Φ8mm | 0~360° | 0.00V~600V | 0mA~600A | 0.0W~12kW | -- |
![]() | ETCR EM4320 Large Caliber Three Phase Digital Phase Voltmeter | Φ40mm | 0~360° | 0.00V~600V | 0.0mA~20.0A | 0.0W~360kW | -- |
![]() | ETCR EM4400 Multifunctional Three Phase Digital Phase Voltmeter | Φ8mm | 0~360° | 0.00V~700V | 0.0mA~20.0A | 0.0W~140kW | 2~21 times |
Product Video