    ETCR EM4000 Double Clamp Digital Phase Voltmeter
  • Product Series : Double Clamp Digital Phase Voltmeter

    • Main Features

      Used to measure single-phase AC phase, current, voltage, leakage current, phase sequence and other power parameters
      Clamp jaw size: Φ8mm
      Voltage range: AC 0V~600V
      Current range: AC 0A~20A
      Phase range: 0°~360°

    Product Introduction

    ETCR EM4000 Double Clamp Digital Phase Voltmeter, also known as single-phase phase voltammeter, digital phase voltammeter, voltammeter, phase measuring instrument, is used for phase, AC current, AC voltage, AC leakage current, and phase sequence measurement.The AC voltage and AC current can be directly measured when the circuit under test is not open, and the phase between the two voltages, the two currents, and the voltage and current can be measured. In addition, the power factor and power of the circuit can be indirectly measured, and the three-phase phase sequence, transformer wiring group, inductive, capacitive circuit, test the secondary circuit and the female difference protection system, read out the phase relationship between the CT of the various groups of mobile protection, check whether the wiring of the meter is correct, and overhaul the line equipment.It is suitable for electric power, petrochemical, metallurgy, railways, meteorology, industrial and mining enterprises, scientific research institutions, metrology departments, etc.


    ETCR EM4000 Double Clamp Digital Phase Voltmeter adopts a large LCD display screen with white screen backlight, and the display is clear at a glance. The instrument adopts an insulated non-slip sheath, has a data retention function, automatic shutdown function, simple operation, reliable and durable.


    1. Input by voltage transformer and current clamp, there is no high voltage in the machine, and the two inputs are completely isolated, which is safe and reliable.
    2. The pointed and small jaws are suitable for places with dense wiring.
    3. The test line adopts a special power cable, and the elastic rod plug and alligator clip are insulated and protected.
    4. The use of large LCD display, white screen backlight, the display is clear at a glance.
    5. High precision, high stability, low power consumption, and easy operation.

    EM4000 (10).jpg


    EM4000 (9).jpg

    Technical Parameters


    1.Range & Basic Error

    CategoryRangeResolutionBasic Error
    Voltage20V0.01V±(0.5% range)
    200V0.1V
    600V1V
    Current200mA0.1mA±(0.5% range)
    2A1mA
    20A10mA
    Phase0~360°±1°

     
    2.General Specifications

    Power SupplyDC9V Alkaline dry battery (1.5V LR6X6)
    Display ModeLCD display, white screen backlight function, suitable for dim places
    LCD Size70mmX62mm; display area: 64mmX54mm
    Clamp Jaw SizeΦ8mm 
    Sampling Rate3 times/second
    RangeAC voltage: 0~20V/200V/600V
    AC current: 0~200mA/2A/20A
    Phase: 0~360°
    The Amplitude Range Of The Measured Signal When Measuring The PhaseWhen measuring the phase of U1-U2: 30V~600V
    When measuring the phase of I1-I2: 10mA~20.00A
    When measuring the phase of U1-I2 or I1-U2: 10V~500V, 10mA~20.00A
    Data HoldPress the HOLD key to hold the data during the test, and the ”DH" symbol is displayed
    Automatic ShutdownAfter about 15 minutes of power-on, the meter automatically shuts down to reduce battery consumption
    Voltage DetectionWhen the battery voltage is lower than 7.8V~8V, the low battery voltage symbol is displayed to remind the battery to be replaced.
    Working CurrentTurn on the backlight up to about 35mA
    Turn off the backlight, the meter consumes about 5mA of power
    Instrument Size196mmX92mmX54mm
    WeightHost: about 565g (include battery); total weight: about 2.24kg (include accessories)
    Insulation≥10MW between the instrument line and the housing, between the two voltage input terminals
    StructureDouble insulation
    Input ImpedanceThe input impedance of each gear of the test voltage is: 1MΩ
    When measuring the phase of U1U2, the voltage input impedance is: 40kΩ
    Withstand VoltageThe sine wave AC voltage of 1000V/50Hz can be tolerated between the instrument line and the housing for 1 minute; the sine wave AC voltage of 500V/50Hz can be tolerated between the two voltage input terminals for 1 minute.
    Working Temperature & Humidity-10℃~40℃; below80%RH
    Store Temperature & Humidity-10℃~60℃; below70%RH


    Model Comparison

    Product PictureProduct Model NameClamp Jaw SizePhaseVoltage RangeCurrent RangePower RangeHarmonic
    EM4000 (1).jpgETCR EM4000 Double Clamp Digital Phase VoltmeterΦ8mm0~360°0.00V~600V0.0mA~20.0A----
    EM4000A (1).jpgETCR EM4000A Double Clamp Digital Phase VoltmeterΦ8mm0~360°0.00V~600V0mA~600A0.0W~12kW--
    EM4020 (1).jpgETCR EM4020 Large Caliber Double Clamp Digital Phase VoltmeterΦ40mm0~360°0.00V~600V0.0mA~20.0A0.0W~360kW--
    EM4300 (1)~1.jpgETCR EM4300 Three Phase Digital Phase VoltmeterΦ8mm0~360°0.00V~600V0mA~600A0.0W~12kW--
    EM4320 (1)~1.jpgETCR EM4320 Large Caliber Three Phase Digital Phase VoltmeterΦ40mm0~360°0.00V~600V0.0mA~20.0A0.0W~360kW--
    EM4400 (4).jpgETCR EM4400 Multifunctional Three Phase Digital Phase VoltmeterΦ8mm0~360°0.00V~700V0.0mA~20.0A0.0W~140kW2~21 times


    Product Video

    Related Products
    ETCR EM4000 Double Clamp Digital Phase Voltmeter
    ETCR EM4000A Double Clamp Digital Phase Voltmeter
    ETCR EM4020 Large Caliber Double Clamp Digital Phase Voltmeter
    • Contact Us

    +86 13802922567 (Johnson Zhang)

    [email protected]

    10th Floor, Block 5, Liandong Intelligent Manufacture Park, No. 105, Shilong North Road, Nanhai District, Foshan City, Guangdong, China

    All Rights Reserved © Guangdong ETCR Electronic Technology CO.,Ltd 2025
    Site Map
    Independent Station

    Home
    Tel
    Product
    Contact