Product Series : High/Low Voltage Clamp Current Meter
Used for measurement of H/L voltage AC current of overhead line below 60kV
Current Measurement Range: AC 0.00mA~600.0A
Clamp Jaw Size: Φ33mm
Wireless transmission distance: 30m
Memory: data storage 99 groups
Product Introduction
ETCR EM9100B Wireless H/L Voltage Clamp Current Meter , also known as overhead line load tester, high voltage load tester, high altitude current tester, high voltage current telemeter, which is used for measurement of H/L voltage of overhead line. The meter is composed of dedicated clamp type current meter and high voltage insulation rod. If do not use an insulating rod, it can also be used as high-precision low-voltage clamp ammeter. It is widely used in substation, power plant, industrial and mining enterprise, testing station, electrician maintenance department for current detection and field electrician operation,etc.
ETCR EM9100B Wireless H/L Voltage Clamp Current Meter is composed of clamp jaw, receiver and insulating rod, the wireless communication distance between the clamp jaw and receiver is 30m. The innovative integrated design of clamp jaw and guidance zone can quickly and easily clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe and fast.The meter also has functions such as data hold, and memory, etc.
1.Suitable for line voltage below 60kV, the insulated rod should be required when measure above 600V.
2.Innovative automatic plug-in/out structure, clamp or remove the tested wire by pressing or pulling the insulating rod, which is safe, efficient and fast.
3.Can be used to measure leakage current.
4.Wireless communication distance: 30m
5.Memory: data storage 99 groups.


Technical Parameters
| Power Supply | DC6V alkaline dry battery (1.5V AAA×4) |
| Display Mode | 4-digit LCD display, backlight function, suitable for dim place |
| LCD Size | 47mm×28.5mm |
| Measurement Method | Clamp CT, integration method |
| Transmission Mode | 433MHz Wireless transmission distance 30m |
| Clamp Jaw Size | Φ33mm |
| Measurement Range | AC 0.00mA~600.0A |
| Current Frequency | 50Hz/60Hz automatic |
| Solution | 0.01mA |
| Shift Gear | 0.00mA~600A Fully automatic shift gear |
| Test Accuracy | 0.00mA~100A: ±1%rdg±5dgt |
| 101A~600A: ±2%rdg±5dgt | |
| Memory | 99 groups, in storage process “MEM” symbol display, “FULL” symbol flicker indicate storage full |
| Line Voltage | Suitable for circuit testing with insulated skin below 60kV, and bare wire or busbar below 35kV.(Operation with insulating rod) |
| Data Hold | Press HOLD key to hold data in test mode, “HOLD" symbol display, press HOLD key again to cancel this function. |
| Data Access | "MR" symbol display, can look up all storage data |
| Sampling Rate | 2 times/second |
| Overflow Display | Exceed measure range overflow function:"OL A" symbol display |
| No Signal Indication | When the receiver has not received transmit signal, dynamic display "no- -"symbol |
| Automatic Shutdown | After 15 minutes power on, the meter shuts down automatically without any operation to reduce battery consumption |
| Battery Voltage | When battery voltage is lower than 4.8V, low battery voltage symbol display and remind to replace battery. |
| Meter Size | 72mm×245mm×39mm |
| Weight | Meter: about 355g (include battery), Receiver: about 330g(include battery), Total weight: about 3.3kg(include accessory) |
| Interference | No 315MHz, 433MHz same frequency signal interference |
| Telescoping Insulating Rod Size | About 4300mm |
| Insulation Strength | AC 60kV/rms (The telescopic insulating rod is completely pulled apart, between the two ends) |
| Structure | Anti-drip typeⅡ |
| Working Temperature & Humidity | -20℃~40℃; below 80%RH |
| Storage Temperature & Humidity | -20℃~60℃; below 70%RH |
Model Comparison
| Product Picture | Product Model Name | Clamp Jaw Size | Line Voltage Level | Current Range | Solution | Max Accuracy | Transmission Method |
![]() | ETCR EM9000 H/L Voltage Clamp Current Meter | Φ48mm | ≤110kV | AC 0mA~1200A | 1mA | ±1%rdg±5dgt | -- |
![]() | ETCR EM9000A H/L Voltage Clamp Current Meter | Φ48mm | ≤110kV | AC 0mA~1200A | 1mA | ±1%rdg±5dgt | Bluetooth 10m |
![]() | ETCR EM9000B Wireless H/L Voltage Clamp Current Meter | Φ48mm | ≤110kV | AC 0mA~1200A | 1mA | ±1%rdg±3dgt | Wireless 30m |
![]() | ETCR EM9000S H/L Voltage Clamp Current Meter | Φ48mm | ≤10kV | AC 0mA~1200A | 1mA | ±1%rdg±5dgt | -- |
![]() | ETCR EM9100 H/L Voltage Clamp Current Meter | Φ33mm | ≤60kV | AC 0.00mA~600A | 0.01mA | ±1%rdg±5dgt | -- |
![]() | ETCR EM9100B Wireless H/L Voltage Clamp Current Meter | Φ33mm | ≤60kV | AC 0.00mA~600A | 0.01mA | ±1%rdg±5dgt | Wireless 30m |
![]() | ETCR EM9100S H/L Voltage Clamp Current Meter | Φ33mm | ≤10kV | AC 0.00mA~600A | 0.01mA | ±1%rdg±5dgt | -- |
![]() | ETCR EM9150B Wireless H/L Voltage Clamp Current Meter | Φ40mm | ≤110kV | AC 0mA~1200A | 1mA | ±1%rdg±5dgt | Wireless 30m |
![]() | ETCR EM9200 H/L Voltage Clamp Current Meter | Φ68mm | ≤60kV | AC 0mA~1200A | 1mA | ±1%rdg±5dgt | -- |
![]() | ETCR EM9200B Wireless H/L Voltage Clamp Current Meter | Φ68mm | ≤60kV | AC 0mA~1200A | 1mA | ±1%rdg±5dgt | Wireless 30m |
![]() | ETCR EM9310B H/L Voltage Clamp Current Meter | Φ128mm | ≤110kV | AC 0.00A~9999A | 0.01A | ±1%rdg±5dgt | Wireless 100m |
![]() | ETCR EM9330B H/L Voltage Clamp Current Meter | Φ128mm | ≤110kV | AC 0.00A~9999A | 0.01A | ±1%rdg±5dgt | Wireless 100m |
Product Video