Product Series : Clamp Earth Resistance Tester(Round Clamp Jaw)
Loop resistance measurement, loop leakage current measurement, lightning protection device tester.
Clamp Jaw Size: Φ32mm
Resistance Range: 0.010Ω~1500Ω;Resolution: 0.001Ω
Current Range: 0.000mA~40.0A;Resolution: 0.001mA
Memory: Data Storage 999 Groups
Alarm Function: Alarm threshold can be set
USB Communication interface
Support Bluetooth communication
Rechargeable Lithium Battery
Product Introduction
ETCR EM2150 Loop Resistance Tester, also known as loop circuit Resistance Tester, which is used for measurement of loop resistance of lightning protection Device and leakage current, judging whether the connection of the lightning protection device is reliable and earth current and troubleshooting. In the loop resistance measurement, no need to disconnect the loop down lead, you can measure the loop resistance and the leakage current at the same time by using clamp meter to clamp the line. This clamp meter fully meets the scope stipulated in the National Meteorological Bureau's Order No. 38 [Lightning Protection Device Testing Qualification Management Measures], and is widely used in construction quality inspection stations, supervision companies, construction units, lightning protection companies, electric power departments, etc. The resistance, current, and test time of are displayed on the screen, and the test results are clear.Equipped with rechargeable lithium batteries, it is easy to use.Sound and light alarm function, data storage, data hold function.Clock function, display the current test time.USB interface data upload function.
1. Fully meet the technical parameter requirements of the National Meteorological Bureau's Order No. 38 [Lightning Protection Device Testing Qualification Management Measures], and the Tool of Lightning Protection Device Detection.
2. Resistance, current, and test time are displayed on the same screen, and the test results are clear.
3.With hold function, storage function, clock function.
4.Alarm function: Alarm threshold can be set
5.USB communication interface.
6.Rechargeable lithium battery.
.jpg)
Commonly Used Test Instruments in the Lightning Protection Industry
| Product Name | Model | Main Parameters |
| Clamp Earth Resistance Tester | EM2000+ | Range: 0~1000Ω, Resolution: 0.01Ω |
| Digital Earth Resistance Tester | Test Current: >20mA (sine wave), Resolution: 0.01Ω | |
| Large Grounding Network Earth Resistance Tester | EM3300B | Test Current: >3A, Resolution: 0.001~99.999Ω, Frequency Optional |
| Soil Resistivity Tester | EM3040B | Four-Wire Measurement, Test Current: >20mA (sine wave) Resolution: 0.01Ω |
| Equipotential Connection Reistance Tester | EM3700 | Test Current: >1A, Four-Wire Test, Resolution: 0.001Ω, With Large Capacity Lithium Battery |
| Clamp Loop Resistance Tester | EM2150 | Resistance Measurement Resolution: 0.001Ω, Current Measurement Resolution: 1uA |
| Lightning Protection Tester | EM3800 | Test Device: MOV, With Large Capacity Lithium Battery |
| Insulation Resistance Meter | EM3460A | 0~1000MΩ |
| Surface Impedance Tester | EM3420 | Measuring Range: 10³~1010Ω |
| Digital Multimeter | EM5930 | Voltage, Current, Resistance Measurement, Resolution: 3.5 Digits |
| Lightning Protection Standard Resistor | EM3900 | 10ˉ³~10⁵Ω,Power 1/2w, Wirewound |
Technical Parameters
1.Measurement Range & Accuracy
| Measurement Mode | Measuring Range | Resolution | Accuracy |
| Resistance | 0.010Ω~0.099Ω | 0.001Ω | ±(1%rdg+0.01Ω) |
| 0.10Ω~0.99Ω | 0.01Ω | ±(1%rdg+0.01Ω) | |
| 1.0Ω~49.9Ω | 0.1Ω | ±(1%rdg+0.1Ω) | |
| 50.0Ω~99.5Ω | 0.5Ω | ±(1.5%rdg+0.5Ω) | |
| 100Ω~199Ω | 1Ω | ±(2%rdg+1Ω) | |
| 200Ω~395Ω | 5Ω | ±(5%rdg+5Ω) | |
| 400Ω~590Ω | 10Ω | ±(10%rdg+10Ω) | |
| 600Ω~880Ω | 20Ω | ±(20%rdg+20Ω) | |
| 900Ω~1500Ω | 30Ω | ±(25%rdg+30Ω) | |
| Current | 0.000mA~0.999mA | 0.001mA | ±(1.5%rdg+0.5mA) |
| 0.00mA~9.95mA | 0.01mA | ±(2%rdg+1mA) | |
| 10.0mA~99.0mA | 0.1mA | ±(2.5%rdg+5mA) | |
| 100mA~300mA | 1mA | ±(2.5%rdg+20mA) | |
| 0.30A~2.99A | 0.01A | ±(2.5%rdg+0.1A) | |
| 3.0A~9.9A | 0.1A | ±(2.5%rdg+0.3A) | |
| 10.0A~19.9A | 0.1 A | ±(2.5%rdg+0.5A) | |
| 20.0A~40.0A | 0.1 A | ±(3%rdg+1A) |
2.Technical Specification
| Power Supply | 3.7V DC(rechargeable lithium battery 2600mAh) |
| LCD Displayer | 4-digit LCD digital display, 47mm×28.5mm |
| Resistance Range | 0.010Ω~1500Ω |
| Resistance Resolution | 0.001Ω |
| Current Range | 0.000mA~40.0A |
| Current Resolution | 0.001mA |
| Resistance Measurement Frequency | >1kHz |
| Measured Current Frequency | 50/60Hz Automatic |
| Memory | 999 groups |
| Communication Interface | USB interface, software monitoring, data upload to computer, dynamic display |
| Self-check Time | ≤1s,Boot up and quickly enter test mode |
| Working Current | ≤50mA |
| Operation Button | 6 soft buttons, straight-through performance |
| Communication Line Length | 1.5m(USB data cable) |
| Clock Function | Display hour and minute |
| Sound & Light Alarm | “Du-Du-Du-" Alarm sound, press the AL Button to turn on and turn off;LCD alarm flashing indication |
| Alarm Threshold Setting Range | Resistance:1Ω~199Ω; Current:1 mA~499mA |
| Automatic Shutdown | The tester flashes for 30S after 5 minutes of no operation, and then automatically shuts down |
| Clamp Jaw Size | Φ32mm |
| Clamp Opening Size | 32mm |
| Tester Size | 260mm×90mm×66mm |
| Weight | About 955g (include battery) |
| Protection Level | Double insulation |
| Structure Feature | Clamp type |
| Measurement Range Gear Shift | Fully automatic shifting |
| Single Measurement Time | 0.5 second |
| Working Temperature & Humidity | -20℃~55℃;10%RH~90%RH |
Model Comparison
| Product Picture | Product Model Name | Clamp Jaw Size | Resistance Range | Current Range | Data Storage | Others |
![]() | ETCR EM2000A Clamp Earth Resistance Tester | 55mm×32mm | 0.010Ω~500Ω | -- | 99 | |
![]() | ETCR EM2000 Clamp Earth Resistance Tester | 55mm×32mm | 0.010Ω~1000Ω | -- | 99 | |
![]() | ETCR EM2000C Clamp Earth Resistance Tester | 55mm×32mm | 0.010Ω~1200Ω | 0.00mA~30A | 99 | |
![]() | ETCR EM2000A+ Clamp Earth Resistance Tester | 65mm×32mm | 0.010Ω~200Ω | -- | 500 | |
![]() | ETCR EM2000+ Clamp Earth Resistance Tester | 65mm×32mm | 0.010Ω~1200Ω | -- | 500 | |
![]() | ETCR EM2000C+ Clamp Earth Resistance Tester | 65mm×32mm | 0.010Ω~1200Ω | 0.00mA~20A | 500 | |
![]() | ETCR EM2000B+ Explosion Proof Clamp Earth Resistance Tester | 65mm×32mm | 0.010Ω~1200Ω | -- | 99 | Explosion proof |
![]() | ETCR EM2100+ Clamp Earth Resistance Tester | 32mm | 0.010Ω~1200Ω | -- | 500 | |
![]() | ETCR EM2100A+ Clamp Earth Resistance Tester | 32mm | 0.010Ω~200Ω | -- | 500 | |
![]() | ETCR EM2100C+ Clamp Earth Resistance Tester | 32mm | 0.010Ω~1200Ω | 0.00mA~20.0A | 500 | |
![]() | ETCR EM2150 Clamp Loop Resistance Tester | 32mm | 0.010Ω~1500Ω | 0.00mA~40A | 999 | Lithium battery USB interface Clock function |
![]() | ETCR EM2200 Multifunctional Clamp Earth Resistance Tester | 65mm×32mm | 0.010Ω~1500Ω | 0.00mA~40A | 999 | Lithium battery USB interface Clock function |
![]() | ETCR EM2300 Ground Pile Type Clamp Earth Resistance Tester | 65mm×32mm | 0.00Ω~20kΩ | 0.000mA~20A | 500 | Soil Resistivity Range Earth Voltage Range |
![]() | ETCR EM2300B Ground Pile Type Clamp Earth Resistance Tester | 65mm×32mm | 0.00Ω~200kΩ | 0.000mA~45A | 500 | Soil Resistivity Range Earth Voltage Range |
Product Video